Construction of a new private
medical facility with operating rooms,
pharmacy, restaurant, kitchen,
mamimography, x-ray rooms, 11 consultation & therapy
rooms,
15 Private patient rooms. 5
storey ramp for handicap access throughout the
building
Reinforced concrete beam & one
way slab construction.
Structure designed for seismic
category 3 and Hurricane wind loads
based on the UBC-97 and AC1
building codes
Preparation of all detailing
of reinforcing steel in accordance with the National
building code of Canada (NBCC) 1995
Design & draughting of exposed
structural steel trellis structure
Coordination of drawings,
answering of site questions, discussions with
geotechnical
engineer by email.
|